• EXAMPLE 1

To measure the residual unbalance, the VA-11B or VA-12 is used to perform frequency analysis and measure the displacement at the rotation speed.
The balance rank G of rotational machinery and the maximum practical rotation speed can be used to calculate the allowable residual unbalance. This value is then compared against the measured residual unbalance, to ensure that a specific limit is not exceeded.

Supported Technical Standard / Law / Regulation
●ISO 1940-1:2003 Mechanical vibration -- Balance quality requirements for rotors in a constant (rigid) state -- Part 1: Specification and verification of balance tolerances

PRODUCT LIST

MODEL PRODUCT NAME REMARKS
VA-11B / VA-12 Field Balancer / Vibration Analyzer